某局点V7无线插卡无法正常堆叠故障排查
一、问题现象
客户现场两台S7510E交换机使用IRF2进行堆叠,现在需要在每台交换机上各增加一块LSQM1WCMX20的无线控制引擎插卡来部署无线业务。并且要求无线控制引擎插卡需要跨框进行IRF2堆叠,现场进行堆叠操作后发现作为IRF Slave的插卡不停在重启,无法聚合成功,并且设备弹出告警信息如下。
%Mar 6 13:57:26:939 2018 AC1 IFNET/3/PHY_UPDOWN: Physical state on the interface Ten-GigabitEthernet1/0/2 changed to up.
%Mar 6 13:57:26:940 2018 AC1 IFNET/5/LINK_UPDOWN: Line protocol state on the interface Ten-GigabitEthernet1/0/2 changed to up.
%Mar 6 13:58:07:353 2018 AC1 IRF/4/IRF_HELLO_TIMEOUT: IRF member 2 hello timed out.
%Mar 6 14:07:05:532 2018 AC1 SHELL/5/SHELL_LOGOUT: Console logged out from con0.
%Mar 6 14:11:31:156 2018 AC1 IRF/4/IRF_HELLO_TIMEOUT: IRF member 2 hello timed out.
二、原因分析
1、首先排除设备硬件故障的可能,查看无线插卡设备指示灯是否正常,确保板卡正确完整插入机框。
2、再次通过命令行查询板卡信息,确保做堆叠设备的版本一致:
<AC1> display version
H3C Comware Software, Version 7.1.064, Release 5218P01
Copyright(c)2004-2017New H3C Technologies Co., Ltd. All rights reserved.
H3C LSQM1WCMX20 uptime is 0 weeks, 0 days, 0 hours, 33 minutes
<AC2> display version
H3C Comware Software, Version 7.1.064, Release 5218P01
Copyright(c)2004-2017New H3C Technologies Co., Ltd. All rights reserved.
H3C LSQM1WCMX20 uptime is 0 weeks, 0 days, 0 hours, 33 minutes
3、然后排查配置侧是否存在问题,下面为现场配置:
AC1无线控制引擎插卡配置:
irf mac-address persistent timer
irf auto-update enable
irf auto-merge enable
irf member 1 priority 32
#
irf-port 1
port group interface Ten-GigabitEthernet1/0/2
#
AC2无线控制引擎插卡配置:
irf mac-address persistent timer
irf auto-update enable
irf auto-merge enable
irf member 2 priority 1
#
irf-port 2
port group interface Ten-GigabitEthernet2/0/2
4、确认配置无误后,再次按照标准的IRF2配置顺序进行配置后发现还是无法堆叠成功,进而查看AC1的日志发现:
%Mar 6 13:57:26:939 2018 AC1 IFNET/3/PHY_UPDOWN: Physical state on the interface
Ten-GigabitEthernet1/0/2 changed to up.
%Mar 6 13:57:26:940 2018 AC1 IFNET/5/LINK_UPDOWN: Line protocol state on the interface Ten-GigabitEthernet1/0/2 changed to up.
%Mar 6 13:58:07:353 2018 AC1 IRF/4/IRF_HELLO_TIMEOUT: IRF member 2 hello timed out.
%Mar 6 14:07:05:532 2018 AC1 SHELL/5/SHELL_LOGOUT: Console logged out from con0.
%Mar 6 14:11:31:156 2018 AC1 IRF/4/IRF_HELLO_TIMEOUT: IRF member 2 hello timed out.
5、通过日志发现AC1应该是发送的hello报文超时导致的,由此联想到两台设备不能正常通信,通过检查STP时,发现交换机Ten-GigabitEthernet1/0/2内联接口被阻断了。
=====================display stp brief=======================
MST ID Port Role STP State Protection
0 Ten-GigabitEthernet1/0/2 ROOT FORWARDING NONE
0 Ten-GigabitEthernet2/0/2 ALTE DISCARDING NONE
三、解决方法
由于V7平台交换机默认开启STP功能自动计算生成树,导致内侧互联端口被阻塞,关闭交换机侧内联接口的STP功能后,成功实现AC插卡的IRF2功能。
2018年06月
本期文章
-
卷首语
-
公司动态
-
行业聚焦
-
产品推荐
-
案例介绍
-
经验共享
-
培训天地